5466-353 WOODWARD
If the panel meters show that the generator voltage is different from that of the bus, the voltage offset potentiometer may need adjustment. Make sure that the
panel meters are accurate, calibrated, and at operating temperature. Most panel meters are accurate to ±3% and are not temperature compensated.
The 9905/9907 series of the Woodward 2301A controls load sharing and speed
of generators driven by diesel or gasoline engines, or steam or gas turbines.
These power sources are referred to as “prime movers” throughout this manual.
The control is housed in a sheet-metal chassis and consists of a single printed
circuit board. All potentiometers are accessible from the front of the chassis.
The 2301A provides control in either isochronous or droop mode.
The isochronous mode is used for constant prime mover speed with:
· Single-prime-mover operation;
· Two or more prime movers controlled by Woodward load sharing control
systems on an isolated bus;
· Base loading against an infinite bus with the load controlled by an Automatic
Power Transfer and Load (APTL) Control, an Import/Export Control, a Generator
Loading Control, a Process Control, or another load-controlling accessory.
The droop mode is used for speed control as a function of load with:
· Single-prime-mover operation on an infinite bus or
· Parallel operation of two or more prime movers.
The following is an example of the typical hardware needed for the 2301A
system controlling a single prime-mover and generator:
· A 2301A electronic control
· An external 20 to 40 Vdc power source for low-voltage models; 90 to 150
Vdc or 88 to 132 Vac for high-voltage models
· A proportional actuator to position the fuel-metering device, and
· Current and potential transformers for measuring the load carried by the
generator.
Applications
The 2301A 9905/9907 series electronic controls have switch-selectable speed
ranges. Any of these control models can be set to operate within one of the
following rated speed ranges:
· 500 to 1500 Hz
· 1000 to 3000 Hz
· 2000 to 6000 Hz
· 4000 to 12 000 Hz
The speed range is factory set for 2000 to 6000 Hz. Refer to the inside
cover to change speed range and prevent possible overspeed. Using
the wrong speed range could cause an overspeed with resulting
damage to equipment and/or personal injury or death.
The Rated Speed potentiometer is the only multi-turn pot in this
control. All other pots are single-turn. Take care not to turn these pots
beyond their stops.
Woodward9907-005
WOODWARD9907-023
WOODWARD9907-1198
WOODWARD9907-166
WOODWARD9907-166M
WOODWARD9907-167
WOODWARD9907-205
WOODWARD9907-345
Woodward9907-345
WOODWARD9907-345 R
WOODWARD9907-838
WOODWARD9907-838
WOODWARDB210438
Woodwardcmw112
WOODWARDD210439
WOODWARDD210452
WOODWARDDB250-397
WOODWARDEC8551-094
WOODWARDEGB13C
WOODWARDEGB-13P
WOODWARDG8516-039
WoodwardWIP11-I1
WOODWARDWOODWARD 5503-215D
WOODWARDWoodward 21
WOODWARDWOODWARD 601-1008
WOODWARDWOODWARD 99
WOODWARDXD1G11
"WOODWARD "5441-407
WOODWARD5437-687
WOODWARD 5466-355
WOODWARD 5501-372
1
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225