5441-695 WOODWARD
To prevent damage to electronic components caused by improper handling, read and observe the precautions in Woodward manual 82715, Guide for Handling and Protection of Electronic Controls, Printed Circuit Boards, and Modules.
If the output is configured as "Impulse", the discrete output
will enable for the time configured in parameter "3416 GCB
time pulse". An external holding coil and sealing contacts
must be installed into the GCB closing circuit if this discrete
output is configured for an impulse output signal.
Steady
If the relay is configured as "Steady", the relay will energize
and remain enabled as long as the discrete input "Reply
GCB" remains de-energized and the generator and busbar
voltages are identical. If a class C or higher alarm occurs,
this discrete will disable and the GCB will open immediately.
Relay output [R
07]
Fixed to "Command: open GCB"
Programmable
Not applicable for application mode A01 .
The parameter ╚═▷ 3403 defines how this relay functions.
• If this output is configured as "N.O.", the relay contacts •
close resulting in the GCB opening circuit energizing.
• If this output is configured as "N.C.", the relay contacts •
open resulting in the GCB opening circuit deenergizing.
•• If this output is configured as "Not used", this relay is
freely configurable. The LogicsManager for Relay 7 is
preconfigured to "04.70 Opening GCB active" (This
pre-configuration is similar to the "N.O." logic).
Relay output [R
08]
Fixed to "Command: close MCB" Only applicable for application mode A04 .
The discrete output "Command: close MCB" is an impulse
output signal.
This discrete output is enabled for the time configured in
parameter "3417 MCB close command".
An external holding coil and sealing contacts must be
utilized with the MCB closing circuit.
Relay output [R
09]
Fixed to "Command: open MCB"
Programmable
Only applicable for application mode A04 .
The parameter ╚═▷ 3398 defines how this relay functions.
•• If this output is configured as "N.O.", the controller
enables this discrete output when the MCB is to be
opened for switching operations.
If the discrete input "Reply MCB" is energized, the
discrete output "Command: open MCB" is disabled.
•• If this output is configured as "Not used", this relay is
freely configurable. The LogicsManager for Relay 9 is
preconfigured to "04.22 Opening MCB active" (This
pre-configuration is similar to the "N.O." logic).
Relay output [R
10]
Programmable
Preconfigured to "Auxiliary services"
The auxiliary services output (LogicsManager 03.01) will be
enabled with the start command (prior to the engine start
because of the prerun time) and remains enabled as long
as the engine is running.
It will be disabled after the engine has stopped and the
postrun time has expired.
The auxiliary services output (LogicsManager 03.01) is
always enabled in MANUAL operation mode.
Relay output [R
11]
Programmable
Preconfigured to "Warning alarm"
This discrete output is enabled when a warning alarm (class
A or B alarm) is issued.
Woodward9907-005
WOODWARD9907-023
WOODWARD9907-1198
WOODWARD9907-166
WOODWARD9907-166M
WOODWARD9907-167
WOODWARD9907-205
WOODWARD9907-345
Woodward9907-345
WOODWARD9907-345 R
WOODWARD9907-838
WOODWARD9907-838
WOODWARDB210438
Woodwardcmw112
WOODWARDD210439
WOODWARDD210452
WOODWARDDB250-397
WOODWARDEC8551-094
WOODWARDEGB13C
WOODWARDEGB-13P
WOODWARDG8516-039
WoodwardWIP11-I1
WOODWARDWOODWARD 5503-215D
WOODWARDWoodward 21
WOODWARDWOODWARD 601-1008
WOODWARDWOODWARD 99
WOODWARDXD1G11
"WOODWARD "5441-407
WOODWARD5437-687
WOODWARD 5466-355
WOODWARD 5501-372
1
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225