Brand:Schneider Model number:140CRA93100
vice: Professional Sales provides 24 hours /7 days online service
Colour:new Warranty: 12 months
Lead Time:3-day working day Country of origin: France
Price: Please contact us Product weight:0.73kg
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
140CRA93100 SCHNEIDER Industrial control module machine spare parts
Rated value (DC) 24 V
Reverse polarity protection Yes
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Input current
From power supply L+, typ. 150 mA
from backplane bus 5 V DC, max. 90 mA
Power loss
Power loss, typ. 4.5 W
Analog inputs
Number of analog inputs 6
permissible input current for current input (destruction
limit), max.
40 mA
Input ranges
● Voltage No
● Current Yes
● Thermocouple No
● Resistance thermometer No
● Resistance No
Input ranges (rated values), currents
● 0 to 20 mA Yes
— Input resistance (0 to 20 mA) 150 Ω; typ. 150 ohms max. 175 ohms
● 4 mA to 20 mA Yes
— Input resistance (4 mA to 20 mA) 150 Ω; typ. 150 ohms max. 175 ohms
Cable length
● shielded, max. 1 000 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; 15 bit + sign
● Integration time (ms) 20 ms @ 50 Hz, 16.7 ms @ 60 Hz
● Interference voltage suppression for interference
frequency f1 in Hz
f=n x (f1 ±0.5 %)
Encoder
Connection of signal encoders
● for current measurement as 2-wire transducer Yes
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Operational error limit in overall temperature range
● Current, relative to input range, (+/-) 0.2 %; 40 µA
6ES73364GE000AB0
Page 1/2 1/30/2023 Subject to change without notice
© Copyright Siemens
Basic error limit (operational limit at 25 °C)
● Current, relative to input range, (+/-) 0.1 %
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
Diagnoses
● Diagnostic information readable Yes
Diagnostics indication LED
● Fail-safe operation Yes
● Group error SF (red) Yes
● Encoder supply Vs (green) No
Potential separation
Potential separation analog inputs
● between the channels Yes
● between the channels and backplane bus Yes
● between the channels and the power supply of the
electronics
Yes
Isolation
Isolation tested with 370V for 1 min
Sta
140CRP93200
140CRP93200C
140DAI34000C
140DAI35300C
140DAI45300C
140DAI54000
140DAI54000C
140DAI54300C
140DAI55300
140DAI55300C
140DAI74000C
140DAI75300C
140DAM59000C
140DAO84000
140DAO84000C
140DAO84010C
140DAO84210
140DAO84210C
140DAO84220C
140DAO85300
140DAO85300C
140DDI15310
140DDI15310C
140DDI35300
140DDI35300
140DDI35300
140DDI35300C
140DDI35310
You are welcome to make an inquiry