Q9200A-1001   Honeywell   Controller module Brand new

Q9200A-1001 Honeywell Controller module Brand new

The controller enclosure is constructed of a plastic base 

plate and a plastic factory-snap-on cover. The cover does 

not need to be removed from the base plate for either 

mounting or wiring. Removable terminal blocks are used 

for all wiring connections, which allow the controller to be 

wired before or after mounting.


Brand:HONEYWELL  

Model numberQ9200A-1001 

Colour:new

Warranty: 12 months

Lead Time:3-day working day

Country of origin: USA

Price: Please contact us

Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

Q9200A-1001   Honeywell   Controller module Brand new 

        

Q7752A-1003   Honeywell   Controller module Brand new


The following list summarizes the various components in the overall PIM connectivity block

diagram.

l The field device connects to the IOTA screw terminals labeled SIG IN(x) and COMMON(x) where

“x” denotes the channel numbers 1 through 8.

l The field sensor pulse output is conditioned by the input protection circuitry and filtered to

reduce unwanted high-frequency noise. The filtered output is fed to the high-speed

differential comparator which has a user-selectable threshold control. From Control Builder,

you can select an appropriate low or high voltage threshold based on the sensor type and the

value of the signal amplitude (Vs).

l Comparator hysteresis is also provided to further reduce false triggering especially for slow

rise/fall time signals.

l Each of the eight PIM input channels are electrically isolated from one another and from

system ground (cabinet ground).

l A comparator monitors the isolated +24 V channel power supply with respect to COMMON(x)

and can detect a problem in the field wiring. If the output of the isolated supply falls below 22V

or rises above 26V, a failure is indicated. Failures can be any of the following;

o A short in the field wiring.

o EXT BIAS(x) pin is shorted to COMMON(x).

o Excessive current is being pulled from EXT BIAS(x) pin.

o Power supply fails for some other reason.

If a failure occurs, the soft failure is reported in Control Builder and Station





.

image.png

.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.