The maximum allowable field wiring resistance between the transmitter and the IOTA connection terminal is dependent upon the voltage requirement of the transmitter. The formula for calculating the maximum wiring resistance for the Series C UIO channel used as an analog input is given by the following equation.
Brand:HONEYWELL
Model number:Q7750A-2003
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA
Price: Please contact us
Product weight:0.22kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Servce: Professional Sales provides 24 hours /7 days online service
Q7750A-2003 Honeywell Power module Brand new
Lower Display
Prompt
Upper Display
Range of Setting or Selection
Parameter Definition
MINorRPM RESET UNITS — selects units of minutes or repeat per
minutes for the I term of the PID algorithm. 20 Repeats
per Minute = 0.05 Minutes per Repeat.
RPM REPEATS PER MINUTE — the number of times per
minute that the proportional action is repeated by reset.
MIN MINUTES PER REPEAT — the time between each
repeat of the proportional action by reset.
CONT1ALG The CONTROL ALGORITHM lets you select the type of
control that is best for your process.
ATTENTION
If the recorder has two controllers
(both enabled), CONT1ALG applies for controller #1
and CONT2ALG applies for controller #2.
ON-OFF ON/OFF is the simplest control type. The output can be
either ON (100%) or OFF (0%). The Process Variable
(PV) is compared with the setpoint (SP) to determine
the sign of the error (ERROR = PV-SP). The ON/OFF
algorithm operates on the sign of the error signal.
· In Direct Acting Control, when the error signal is
positive, the output is 100%; and when the error
signal is negative, the output is 0%. If the control
action is reverse, the opposite is true. An adjustable
overlap (Hysteresis Band) is provided between the on
and off states.
· Other prompts affected: “OUT HYST”
DUPLEX ON/OFF is an extension of this algorithm
when the output is configured for Duplex. It allows the
operation of a second ON/OFF output. There is a
deadband between the operating ranges of the two
inputs and an adjustable overlap (hysteresis) of the on
and off states of each output. Both Deadband and
Hysteresis are separately adjustable. With no relay
action the controller will read 50%.
· Other prompts affected: “OUT HYST” and
“DEADBAND”
.
.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225