Each controller is programmable because the user chooses which function blocks to use and how to connect
them. It is configurable because each Function Block has
user-defined behavior.
Brand:HONEYWELL Model number:FSC 10012/1/2
Colour:new Warranty: 12 months
Lead Time:3-day working day Country of origin: USA
Price: Please contact us Product weight:0.22kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Servce: Professional Sales provides 24 hours /7 days online service
FSC 10012/1/2 Honeywell Controller module Brand new
Select the input stream type in the Input Stream Type box. You can select one of the following:
l Single Stream - You can select this option for all channels.
l Dual Stream - You can select this option only for odd-numbered channels.
Whenyou configure a channel for Dual Stream, its associated even-numbered channel
number appears in the Associated Channel Number box.
For example, if you have configured channel 1 for dual stream, the channel number 2 appears
in the Associated Channel number box.
ATTENTION
l When you select the pulse input channel type as Pulse Input with Fast Cutoff
for Fast Cutoff channels (channel 7 and channel 8), Single Stream is selected
by default and is non-editable.
l When you select the pulse input channel type as Pulse Input, you can
configure Dual Stream on the Fast Cutoff channels (channel 7 and channel 8).
l Dual Stream option is not applicable for Fast Cutoff channels (channel 7 and
channel 8) when the Pulse Input Channel type as Pulse Input with Fast Cutoff.
In this scenario, the option Single Stream is selected by default and is noneditable.
l If you select the Input Stream Type as Dual Stream for odd-numbered
channels, then you cannot configure their associated even numbered
channels. For example, if you have configured channel 1 as Dual Stream, you
cannot configure channel 2. In addition, the associated channel does not
appear in the tree view if you have configured the channel for Dual Stream.
l If the CM already contains the even-numbered channel and you try to
configure its associated odd-numbered channel as Dual Stream, an error
message appears. You need to delete the associated even-numbered channel
from the CM. For example, if a CM contains channel 3 and channel 4, and you
try to configure channel 3 as Dual Stream, an error message appears. You
need to delete channel 4 to configure channel 3 as Dual Stream.
l When a channel is configured for Dual Stream, the Status Data tab of the PIM
does not display any values for the associated channel in the Monitoring view.
For example, if you have configured channel 3 for Dual Stream, the channel 4
row in the Status Data tab does not display any values.
.
.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225