D03-3003-000 Honeywell
If multiple instruments need a ground reference the four positions of TB2 can serve as those ground points (assuming the JP17-JP20) jumpers are intact. If more than four grounding screws are needed then a custom wire from TB2 to a separate terminal block can allow for more grounding screw positions.
In all cases the System 57 operates as a MODBUS Remote Terminal
Unit (RTU), acting as a slave device node and transmitting data onto
the communication line only in response to a request from a master
device. The host computer system, typically a PLC, DCS or SCADA
graphics package, acts as the master device controlling the
communication system operation.
The subset of MODBUS functions supported by the System 57 RTU
are 02, 03, 04, 06 and 16. The MODBUS broadcast commands are not
supported and will be ignored, however, global commands are available
to reset all cards in the rack simultaneously. For a detailed description
of the available commands and data formats refer to the System 57
MODBUS Function Reference given in Section 7.
2.2 MODBUS INTERFACE MODULE - RS485/422
2.2.1 General
The RS485/422 Interface Module has two differential 5V transceivers
designated channel 1 and channel 2. Each transceiver channel can be
resistively terminated by setting LK1 and LK2 respectively (see Figure
1 and Section 3.4.3). The interface signals are isolated from the
System 57 power supply 0V and Ground to protect the host computer
against damage due to earth loops.
2.2.2 RS485 Operation
An outline RS485 connection diagram is shown in Figure 4.
When configured for the RS485 mode, transceiver Channel 1 is used
in dual highway systems for the primary highway or the only highway
in single highway systems. Transceiver Channel 2 is used only in dual
highway systems where it functions as the secondary highway.
Depending upon the type of installation, operation is possible over
distances up to 1.2km (3900ft). In the multi-drop mode up to 32 nodes,
including the host, can be connected. The terminal connections are:
CH1-A, CH1-B Differential Transceiver Channel 1 (Primary).
CH2-A, CH2-B Differential Transceiver Channel 2 (Secondary).
DGND Isolated Data Ground.
In a dual highway system the MODBUS uses, at any one time, only
one of the two available highways, either the primary or the secondary.
The interface automatically switches between highways when a
communication failure is detected.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225