CC-PAOX01  Honeywell  Controller module Brand new

CC-PAOX01 Honeywell Controller module Brand new

While this information is presented in good faith and believed to be accurate, Honeywell disclaims

the implied warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.


Brand:HONEYWELL   Model numberCC-PAOX01

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

CC-PAOX01  Honeywell  Controller module Brand new      



 The MS/TP MAC address for each device must be set to a 
unique value in the range of 0-127 on an MS/TP network 
segment. DIP switches on the Spyder BACnet controller 
are used to set the controller's MAC address.
Device Instance Number
The Device Instance Number must be unique across the 
entire BACnet system network because it is used to 
uniquely identify the BACnet devices. It may be used to 
conveniently identify the BACnet device from other 
devices during installation. The Spyder BACnet 
Controllers Device Instance Number is automatically set 
when it is added to a WEBStation-AX project. The Device 
Instance Number can be changed by the user, which may 
be necessary when integrating with a third party or when 
attempting to replace an existing controller and it is 
desired to maintain the existing Device Instance Number.
NOTE: For complete instructions on how to set the 
MS/TP MAC address or set the Device Instance 
Number refer to the Installation Instructions, 
form 62-0310.
Termination Resistors
Matched terminating resistors are required at each end of 
a segment bus wired across (+) and (-). Use matched 
precision resistors rated 1/4W ±1% / 80 - 130 Ohms. 
Ideally, the value of the terminating resistors should 
match the rated characteristic impedance of the installed 
cable. For example, if the installed MS/TP cable has a a 
listed characteristic impedance of 120 Ohm, install 120 
Ohm matched precision resistors.
NOTE: The controller does not provide any network biasing.
Shield Terminating
Following proper MS/TP cabling shield grounding 
procedures is important to minimize the risk of 
communication problems and equipment damage caused 
by capacitive coupling. Capacitive coupling is caused by 
placing MS/TP cabling close to lines carrying higher 
voltage. The shield should be grounded on only one end of 
the MS/TP segment (typically the router end). Tie the 
shield through using the SHLD (terminal 4) on the Spyder 
BACnet Controller.
Sylk Bus
Sylk is a two wire, polarity insensitive bus that provides 
both 18 VDC power and communications between a Sylkenabled sensor and a Sylk-enabled controller. Using Sylkenabled sensors saves I/O on the controller and is faster 
and cheaper to install since only two wires are needed and 
the bus is polarity insensitive. Sylk sensors are configured 
using the latest release of the Spyder Tool for WEBPro and 
WEBStation. 




.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.