8C-PDOD51 Honeywell
The controller enclosure is constructed of a plastic base
plate and a plastic factory-snap-on cover. The cover does
not need to be removed from the base plate for either
mounting or wiring. Removable terminal blocks are used
for all wiring connections, which allow the controller to be
wired before or after mounting.
Event pen function
If Function prompt “PEN 1IN” under Set-up prompt “PEN 1” has been configured as DGTL1 or DGTL2,
the pen (channel) operates as an “event pen” and tracks the remote contact (switch) closure by way of the
digital 1 or digital 2 input wired to the alarm output/digital input printed circuit board.
Event pen operation
When the switch opens, the pen for the channel tracks at the configured OFF position (0-100%) on the
chart.
When the switch closes, the pen tracks at the configured ON position (0-100%) on the chart and tracks at
this position until the switch is opened.
Thus, the “Event Pen” record makes it easy to monitor the on/off operation of an external event.
5.15 Maximizing Pen Life
Steps for maximizing pen life
87HTable 5-29 lists nine steps that will help to maximize the life of your chart pen.
Table 5-29 Maximizing pen life
Step Action
1 Store the chart paper in a cool, clean dry place where the temperature does not exceed 40°C
(104°F) and the humidity is below 65% RH.
2 Do not expose the pen tip and chart paper to abrasive chemicals or dust that cause excessive
pen wear.
3 If the recorder is used in a dusty atmosphere, provide a positive ‘clean air purge’ to minimize
dust particle accumulation on the chart paper.
4 Periodically clean the pen arm using a cotton swab dipped in alcohol. This is more important
when the recorder is located in a dusty environment and no ‘clean air purge’ is used.
5 Never let the pen tip ride on the chart plate when the paper is not present. Use the pen lifter to
raise the arm when changing the paper.
6 Keep the door closed while recording.
7 Always insert the pen arm tip into the shipping sponge when storing or shipping the recorder.
8 Be sure that the chart paper lays flat against the chart plate. Any ripple in the paper will cause
light pen printing.
9 Be sure the chart hub assembly is pushed onto the motor shaft so that it is flush with the chart
plate.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225