8C-PDILA1   Honeywell
8C-PDILA1   Honeywell
8C-PDILA1   Honeywell

8C-PDILA1 Honeywell

Brand:HONEYWELL  

Model number8C-PDILA1 

Colour:new

Warranty: 12 months

Lead Time:3-day working day

Country of origin: USA

Price: Please contact us

Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servzce: Professional Sales provides 24 hours /7 days online service

8C-PDILA1   Honeywell


The maximum allowable field wiring resistance between the transmitter and the IOTA connection terminal is dependent upon the voltage requirement of the transmitter. The formula for calculating the maximum wiring resistance for the Series C UIO channel used as an analog input is given by the following equation.

      

8C-PAOHA1   Honeywell

Introduction

The digital input option detects the state of external contacts wired to it. On contact closure, the recorder 

responds according to how each digital input is configured.

· Make your selection under Set Up group “CONTROL1” or “CONTROL2”, function group prompt 

“REM SW”: see Subsection 3.10—Table 3-7 or Subsection 4.6—Table 4-5.

Action on contact closure

84HTable 5-26 lists the configuration prompt selections, the “Action on Contact Closure”, and the display 

indication for each selection available.

Table 5-26 Digital input option action on contact closure

REM SW

Selections

Display Indication Action on Contact Closure

None None No Digital Input selection

To MAN “MAN” blinks Puts the recorder into manual mode; contact open 

returns the recorder to former mode unless AUTO/MAN 

key is pressed while digital input is active.

To LSP “RSP” blinks Puts the recorder into local setpoint 1(switches out of 

remote). When contact opens, the recorder returns to 

former operation unless the FUNC key is pressed while 

digital input is active.

To 2SP “RSP” blinks Puts the recorder into local setpoint 2.

To DIR None Selects direct controller action (transfer if in reverse).

RN/HOLD “H” blinks in upper display Suspends setpoint program or setpoint ramp.

· Keyboard takes priority over external switch for 

RUN/HOLD function.

· Contact open runs the program or ramp.

· If initially in the HOLD state, close then open the 

contact to remotely start the SP ramp or program.

TUNE TUNING x Initiates Accutune.

image.png

We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.