The maximum allowable field wiring resistance between the transmitter and the IOTA connection terminal is dependent upon the voltage requirement of the transmitter. The formula for calculating the maximum wiring resistance for the Series C UIO channel used as an analog input is given by the following equation.

Brand:HONEYWELL   Model number51401551-601

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

51401551-601   Honeywell   Controller module Brand new


        

image.png


PV and SP Processing

The SVP_REGCTL block accepts the following inputs.

l Process Variables (PV1 and PV2) from the SVP_AI channel based on the PVSOURCE

configuration.

l Set Point value from the AUXILIARY function blocks that reside in the C300 - 20mS CEE

Controller when the MODE is set to 'Cascade.'

Process Variable (PV) Processing – fetches the input values (PV1 and PV2) from the SVP_AI

channel based on the status (PV1STS and PV2STS) of the input values and gives the output PV

value. The inputs PV1 and PV2 act based on the selection of preferred PV source (PREFPVSRC)

parameter.

Set Point (SP) Processing – obtains the SP value from the AUXILIARY function blocks when the

MODE is set to 'Cascade' and processes it to perform SP limit checking, SP value must be within the

engineering unit range defined by PVEUHI and PVEULO.

10.25.2 PV handling when PVSTS is BAD

1. If the PVxSTS (x=1, 2) is set to 'BAD',

l the PVSTSFL.BAD is set to 'ON' in the SVP_REGCTL channel,

l MODE is set to 'MAN' in the SVP_AO channel.

l the calculated variable (CV) is set to 'NaN' to invoke Bad Control processing.

l the BADCTLFL is set to 'High.'

NOTE

l When the PV is 'Bad,' AO Mode change is prohibited until PVSTS returns to 'Normal'

if the MODE was in 'Shed.'

l When the PV returns to 'Normal,' the channel remains in 'Manual' mode if the

MODE was in 'Shed.' You must manually change the MODE to 'Normal.'

1. If the PVxSTS (x=1, 2) is set to 'Normal',

l the PV value is normal in SVP_AI channel, and

l the PVSTSFL.NORM is set to 'ON' in the SVP_REGCTL channel.



.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.