Brand:HONEYWELL
Model number:51401551-600
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA
Price: Please contact us
Product weight:0.22kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Servce: Professional Sales provides 24 hours /7 days online service
51401551-600 Honeywell Input module
In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information and specifications in this document are subject to change without notice.
The CV can be set to 'NaN' if the SVP_REGCTL PV is bad or the CV range (CVEUHI/CVEULO) is bad.
The SVP_REGCTL block performs the following actions when the CV changes from good-to-bad.
l Sets BADCTLFL to 'ON' to indicate that a Bad Control condition exists.
TIP
l The SVP_REGCTL block performs the following when the CV is set to 'Bad.'
l requests its primary to initialize if the MODE is shed to 'MAN.'
l indicates to its primary that it is wound-up (ARWET = HiLo) and does not request the
primary to initialize if the MODE is not shed to 'MAN.'
l CV is prohibited to change its value until CV returns to good if the MODE was shed to
'MAN.'
l The SVP_REGCTL block performs the following when the CV changes from 'Bad' to
'Good.'
l remains at 'MAN' mode and continuously sends INITREQ to it primary if the MODE
sheds to 'MAN.' You must change the SVP_REGCTL's MODE to normal.
l clears it wind-up condition and performs a one-shot initialization if the MODE is not
shed to 'MAN.' In addition, it requests the primary to perform the one-shot
initialization.
If the CV is 'Good'
The SVP_REGCTL block determines if the CV is represented in terms of percentage or engineering
units (EUs). If the CV is in EUs, it is converted to percentage.
10.25.15 Output Limiting
This function enforces the following limit checks to the OP value because the MODE is not 'MAN.'
l Normal high or low limits (OPHILM and OPLOLM) - define normal high and low levels for the
OP value. If another function block or user program attempts to store an OP value that exceeds
OPHILM or OPLOLM, the value is clamped to the limit. Only the operator is allowed to store an
OP value that exceeds these limits. The following flags are set when the operator stores the OP
value.
o 'normal limit exceeded' flag (OPHIFL or OPLOFL)
o 'OP Anti-Reset Windup status'
l Extended high or low limits (OPEXHILM and OPEXLOLM) - define the extended high and low
limits for OP. If the operator attempts to store an OP value that exceeds OPEXHILM or
OPEXLOLM, the value is clamped to the limit.
ATTENTION
Default OP limit values for the SVP_REGCTL channel is same as the C300-PID block even if
the SVP_AO channel's OP limit values are 0% and 100% when the SVP_AO is configured as
'Incremental.'
.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225