51304493-200   Honeywell
51304493-200   Honeywell
51304493-200   Honeywell

51304493-200 Honeywell

Brand:HONEYWELL  

Model number51304493-200 

Colour:new

Warranty: 12 months

Lead Time:3-day working day

Country of origin: USA

Price: Please contact us

Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

51304493-200   Honeywell


The controller can be mounted in any orientation. 

Ventilation openings are designed into the cover to allow 

proper heat dissipation, regardless of the mounting 

orientation.

      

51304493-200   Honeywell

ATTENTION

When MODE is ' ;Manual,' OPBIAS is not used (because OP is not calculated). Consequently,

when MODE changes to Manual, OPBIAS is not recomputed.

l You can store to OPBIAS only if the function block is inactive or MODE is 'Manual.' Hence,

prevent a bump in OP is prevented when the bias is changed.

l When you store values to OPBIAS, the following occurs.

o Total bias (OPBIAS) and fixed bias (OPBIAS.FIX) are both set to a new value.

l There are no limit checks applied when you store the OPBIAS. However, after the bias is added

to the calculated variable (CV), the result is compared against the OP limits and clamped, if

necessary.

l You can store to OPBIAS.FIX only if the function block is inactive and SVP_REGCTL is

configured with the control algorithm equation as 'E.' When you store to OPBIAS.FIX, the

following occurs.

o Total bias (OPBIAS) and fixed bias (OPBIAS.FIX) are both set to a new value.

10.25.9 Time-out monitoring

If MODE is set to 'Cascade,' SVP_REGCTL channel monitors its SP input value (that is, primary

input) for time-out. If a valid SP value is not received within the predefined time, the SVP_REGCTL

channel invokes time-out processing. The time-out time (in seconds) is specified by TMOUTTIME.

l Enable time-out monitoring by setting TMOUTTIME to a non-zero value.

l Disable time-out monitoring by setting TMOUTTIME to zero.

10.25.10 Time-out processing

A time-out can occur for several reasons communication error, inactivation of primary block, and

so on. If an input times-out, SVP_REGCTL channel performs setting a time-out flag (TMOUTFL),

requesting the primary block to initialize, and shedding the SVP_REGCTL channel to a predefined

mode (TMOUTMODE).

If MODE is set to 'Cascade' and the SP time-out, the SVP_REGCTL channel performs the following:

l Sets a time-out flag (TMOUTFL).

l Requests the primary to initialize.

ATTENTION

In SVP_REGCTL channel, the primary can be an ENHGENLIN block and AUXILIARY

Function block from C300-20mS CEE Controller and no initialization happens to it.

image.png

We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.