51304042-100 Honeywell
In virtually all configurations, the C300 controller and Series C I/O provides useful, maintainable process equipment connections in a smaller footprint than existing competitors and Honeywell equivalent products. Installing Series C I/O modules contributes to overall total installed cost savings.
To configure the DO channel for ganging
1. Click File > New >I/O Modules > Series_C_I_O > UIO – Universal I/O, 32 channels.
The UIO module appears in the Project view under the Unassigned items.
2. Assign the UIO module to an IOLINK that is configured as "SERIES_C_IO_TYPE."
3. From the Project view, right-click the UIO channel and then click Block Properties.
The UIO channel configuration form appears.
4. Click the Channel Configuration tab.
The Channel Configuration tab configuration form appears. The point type is selected as DI,
by default.
5. Configure the Channel Point Type as DO for which ganging needs to be enabled.
ATTENTION
An error message appears if you try to change the channel type when the channel
is configured in any Control Module.
6. Click OK.
7. Click File > New > Control Module.
The Control Module chart opens.
8. Drag the DO channel from the Project view to the Control Module chart.
9. Double-click the DO channel.
The DO channel configuration form appears.
10. Click the Configuration tab.
The Configuration tab configuration form appears.
11. Select the Enable Ganged Outputs check box.
The Number of Channels Ganged drop-down list is enabled for configuration.
12. Select the number of channels to be ganged from the Number of Channels Ganged dropdown list.
You may encounter errors if one of the following scenarios exists.
l Adjacent channel is not configured as DO channel.
l DO channel, which needs to be configured for ganging, is already configured in any
Control Module.
13. Click OK.
14. Save and close the Control Module chart.
15. Assign and load the Control Module.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225