30754536-001   Honeywell   Power module Brand new

30754536-001 Honeywell Power module Brand new

When a module is configured as non-redundant and uses a redundant IOTA, ensure that the lower slot is kept empty or if a module is plugged into the bottom slot, make sure that the module MUST be powered off.

Brand:HONEYWELL   Model number30754536-001

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

30754536-001   Honeywell   Power module Brand new   


        

image.png




The green LED, DS1, on the IOTA adjacent to terminal block TB2 illuminates if either the Series C

system 24V internal system supply or an external user supplied power source is properly

connected to TB2. If this LED does not illuminate, check wiring to TB2, fuse F3, or the field wiring.

If TB2 is not used (no wires attached), then LED DS1 does not illuminate and this is normal.

6.6.3 Examples to illustrate sensor power connections through TB2

Example 1: Sensor powered from Series C System +24 V internal supply.

Connections made through TB1, FLDPWR(x)+ and COMMON(x)

The following figure displays a sample diagram where the sensor is powered from Series C system

+24 V internal supply and the power connections are made through TB1, FLDPWR(x)+ and

COMMON(x).

- 227 -

Chapter 6 - Series C PIM connectivity

Figure 6.9 Sensor powered from Series C System +24 V internal supply. Connections made through

TB1, FLDPWR(x), and COM(x)

For this type of connection, you need four wires. Two wires provide power to the sensor and the

other two wires connect the pulse output from the sensor to the PIM. This example shows the field

sensor connected to channel 1 but the procedure applies to the remaining channels.

The internal +24 Vdc supply, TB1, and TB2 are used to supply sensor power. This is accomplished

by connecting the corresponding channel’s FLDPWR1+ pin and COMMON1 pin to the positive and

negative power leads of the field sensor respectively. To complete the circuit, place the jumper wire

across the pins of the COM1 terminal block as illustrated in the above diagram so that so field

return is tied to COMMON1.

Install wires at TB2 as illustrated in the above diagram to feed all eight of the FLDPWR(x) to TB1.

There is no need to add individual wires from FLDPWR(x) to the +EXT 12V/24V connector at TB2 as

this is provided by internal copper tracks on the IOTA.

For clarity, the LED DS1 and other components are not shown in the above diagram. See also

figure PIM TB1 pin assignments.


.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.