Brand:HONEYWELL
Model number:30752588-001
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA
Price: Please contact us
Product weight:0.22kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Servce: Professional Sales provides 24 hours /7 days online service
30752588-001 Honeywell
The controller can be mounted in any orientation.
Ventilation openings are designed into the cover to allow
proper heat dissipation, regardless of the mounting
orientation.
To achieve fast reliable data connections good quality screened twisted
pair cable should be used. The maximum achievable data rate is
limited by the cable capacitance and therefore the cable length should
be kept as short as possible. In dual highway configurations a separate
twisted pair should be used for each highway, however if required,
these may be contained within a single cable.
In order to ensure the correct operation and to meet European
Standards for RFI and EMC, it is recommended that all field cables
should be of the screened type with the cable screen connected at one
end only. If the screen is to be connected at the System 57 end, use
either the ground terminal of the DC Input Card, the cabinet using a
suitable metal cable gland or other suitable instrument earth point.
3.4.3 RS485/422 Transmission Line Termination
In RS485 or RS422 applications, the two wire transmission lines must be
properly terminated. The simplest form of termination is typically with a
120 ohm resistor connected across the differential input as follows:
a. In RS422 host systems, a terminator resistance is only required at
the receiver device located in the host and at the receiver device
located in the System 57 node at the far end of the cable.
b. In RS485 host systems a terminator resistance is required at the
transceiver device located in the host and at the transceiver device
located in the System 57 node at the far end of the cable. For dual
highway RS485 systems both highways should be terminated as
described.
Jumper links are provided on the System 57 RS485/422 Module to
make above termination easy (see Figure 1).
In general RS485 transmitter circuits are specified as being capable of
driving a minimum load resistance of 60 ohms, therefore no more than
two terminator resistors should be connected in parallel onto any one bus.
RS422 transmitter circuits are specified as being capable of driving a
minimum load resistance of 100 ohms, therefore no more than one
terminator resistor should be connected onto any bus.
3.4.4 RS485 Network Biasing Resistors
Note: In most systems network biasing resistors are not required. It is
recommended that these resistors are only added as part of a
troubleshooting procedure
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225