NOTE
TB1: This is done through a 145 ohm resistor inline with a Positive Temperature Coefficient
(PTC) device that acts like a fuse (but never needs replacement). Thus, these field terminals
can be permanently shorted to ground without damage. This is an improvement over
Process Manager due to the inclusion of the PTC device.
5.2.5 Analog Input HART module wiring reference table
The following table summarizes the possible Analog Input wiring connections.
Input style Connection characteristics
Standard 2-wire transmitter
l Can use any of the 16 channels.
l No custom wiring required.
Standard self-powered
transmitter
l Can use any of the 16 channels.
l No custom wiring required.
Self-powered transmitter with
loop power(system ground)
l Can use any of the 16 channels.
l Custom wiring is required for channels 1-12: you must find
a screw terminal at ground for one leg of the transmitter.
Self-powered 3-wire transmitter
(system ground)
l Can use any of the 16 channels.
l Custom wiring is required for channels 1-12: you must find
a screw terminal at ground for one leg of the transmitter.
Table 5.8 Summary - Analog Input wiring connections
5.2.6 Allowable field wiring resistance - Analog Input HART module
The maximum allowable field wiring resistance between the transmitter and the IOTA connection
terminal is dependent upon the voltage requirement of the transmitter. The formula for
calculating the max wiring resistance for the Analog Input is given by the following equation.
Rmax = [(13.0 - Vtx) / (0.022)]
where: Vtx = Voltage required at the transmitter terminal
5.2.7 IOTA board and connections - Analog Input HART module
Series C Analog Input 6 inch, non-redundant IOTA and field wiring connection is displayed in the
following imag
.
.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225