The MS/TP MAC address for each device must be set to a
unique value in the range of 0-127 on an MS/TP network
segment. DIP switches on the Spyder BACnet controller
are used to set the controller's MAC address.
Brand:HONEYWELL Model number:30733155-001
Colour:new Warranty: 12 months
Lead Time:3-day working day Country of origin: USA
Price: Please contact us Product weight:0.22kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Servce: Professional Sales provides 24 hours /7 days online service
30733155-001 Honeywell Power module Brand new
MS/TP MAC Address
The MS/TP MAC address for each device must be set to a
unique value in the range of 0-127 on an MS/TP network
segment. DIP switches on the Spyder BACnet controller
are used to set the controller's MAC address.
Device Instance Number
The Device Instance Number must be unique across the
entire BACnet system network because it is used to
uniquely identify the BACnet devices. It may be used to
conveniently identify the BACnet device from other
devices during installation. The Spyder BACnet
Controllers Device Instance Number is automatically set
when it is added to a WEBStation-AX project. The Device
Instance Number can be changed by the user, which may
be necessary when integrating with a third party or when
attempting to replace an existing controller and it is
desired to maintain the existing Device Instance Number.
NOTE: For complete instructions on how to set the
MS/TP MAC address or set the Device Instance
Number refer to the Installation Instructions,
form 62-0310.
Termination Resistors
Matched terminating resistors are required at each end of
a segment bus wired across (+) and (-). Use matched
precision resistors rated 1/4W ±1% / 80 - 130 Ohms.
Ideally, the value of the terminating resistors should
match the rated characteristic impedance of the installed
cable. For example, if the installed MS/TP cable has a a
listed characteristic impedance of 120 Ohm, install 120
Ohm matched precision resistors.
NOTE: The controller does not provide any network biasing.
.
.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
HONEYWELL 30750338-005
HONEYWELL 51403393-100
HONEYWELL 30751044-4
HONEYWELL 30751044-009
HONEYWELL 30751044-7
HONEYWELL 51403393-200
HONEYWELL 4DP7APXIO211
HONEYWELL 30750318-2
HONEYWELL 30750318-3
HONEYWELL 51196882-100
HONEYWELL 51304095-100
HONEYWELL 51400997-200
HONEYWELL 51401088-100
HONEYWELL 51400926-100
HONEYWELL 51304537-100
HONEYWELL 51401583-200
HONEYWELL 51401583-100
HONEYWELL 51401996-100
HONEYWELL 51304421-100
HONEYWELL 51304441-175
HONEYWELL 51107137-117
HONEYWELL 51196654-100
HONEYWELL 51196653-100
HONEYWELL 51400712-100
HONEYWELL 51204166-175
HONEYWELL 51401201-100
HONEYWELL 51401577
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225