30732425-001   Honeywell


Series-C I/O modules are constructed to support normal field failures, wiring errors and conditions such as a shorted wire. All Series-C IOTAs contain at least one fuse that provides protection for catastrophic errors in the IOTA, IOM and other elements of the Series-C system. In normal operation as well as many abnormal operations, the fuse element should not blow.

      

900RSM-0001   Honeywell

5.6 MMF-302 Wiring Diagrams

Following are wiring diagrams that concern NFPA Class B and Class A Initiating Device Circuits (IDCs) using MMF-302 Zone Inter face Modules.

5.6.1 Wiring a NFPA Class B IDC with an MMF-302

Connect the SLC wiring to the module terminals 1 (–) and 2 (+).

Each module takes one address on the SLC. Use the rotary switches on the module to set it to the required SLC address. Refer to “Setting 

an SLC address for a Single Point Module” on page 33.

The IDC is supervised and power limited to 230 microamperes @ 24 VDC.

The figure below shows typical wiring for a supervised and power-limited NFPA Class B IDC using an MMF-302 module.

• Refer to the Device Compatibility Document for compatible smoke detectors.

• 24 VDC power must be provided from a UL listed power supply for fire protection use. This power is inherently supervised by the

module.

• See “Power Considerations” on page 63 for information on 24 VDC power.

SLC

IDC

MMF-302

Two-wire 

smoke 

detectors

3.9K ELR

(supplied with module)

24 VDC Resettable power.

90 mA External 24 volt 

supply required 

Figure 5.15 Typical Class B IDC Wiring with an MMF-302

SLC-idcB2tpH.wmf

FireLite SLC Wiring Manual — P/N 51309:R3 7/29/2019 41

MMF-302 Wiring Diagrams Monitor Modules

5.6.2 Wiring a NFPA Class A IDC with an MMF-302

Connect the SLC wiring to the module terminals 1 (–) and 2 (+).

Each module takes one address on the SLC. Use the rotary switches on the module to set it to the required SLC address. Refer to “Setting 

an SLC address for a Single Point Module” on page 33.

The figure below shows typical wiring for a supervised and power-limited NFPA Class A IDC using an MMF-302 module. 

• Refer to the Device Compatibility Document for compatible smoke detectors.

• 24 VDC power must be provided from a UL listed power supply for fire protection use. This power is inherently supervised by the

module.

• See “Power Considerations” on page 63 for information on 24 VDC power.

image.png

We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.