30731820-001   Honeywell    Input module Brand new

30731820-001 Honeywell Input module Brand new

Because the maximum transmitter output level is -7 dB, and the maximum receiver input level is -10 dB, the receiver may be overdriven on a short link and may require a 3 dB attenuator. Connector allowances for the transmitter and receiver are included in the above power declaration

Brand:HONEYWELL   Model number30731820-001

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

30731820-001   Honeywell    Input module Brand new


        

image.png



NOTE

TB1: This is done through a 145 ohm resistor inline with a Positive Temperature Coefficient

(PTC) device that acts like a fuse (but never needs replacement). Thus, these field terminals

can be permanently shorted to ground without damage. This is an improvement over

Process Manager due to the inclusion of the PTC device.

5.2.5 Analog Input HART module wiring reference table

The following table summarizes the possible Analog Input wiring connections.

Input style Connection characteristics

Standard 2-wire transmitter

l Can use any of the 16 channels.

l No custom wiring required.

Standard self-powered

transmitter

l Can use any of the 16 channels.

l No custom wiring required.

Self-powered transmitter with

loop power(system ground)

l Can use any of the 16 channels.

l Custom wiring is required for channels 1-12: you must find

a screw terminal at ground for one leg of the transmitter.

Self-powered 3-wire transmitter

(system ground)

l Can use any of the 16 channels.

l Custom wiring is required for channels 1-12: you must find

a screw terminal at ground for one leg of the transmitter.

Table 5.8 Summary - Analog Input wiring connections

5.2.6 Allowable field wiring resistance - Analog Input HART module

The maximum allowable field wiring resistance between the transmitter and the IOTA connection

terminal is dependent upon the voltage requirement of the transmitter. The formula for

calculating the max wiring resistance for the Analog Input is given by the following equation.

Rmax = [(13.0 - Vtx) / (0.022)]

where: Vtx = Voltage required at the transmitter terminal

5.2.7 IOTA board and connections - Analog Input HART module

Series C Analog Input 6 inch, non-redundant IOTA and field wiring connection is displayed in the

following imag

.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.