10311/2/1   Honeywell   Controller module Brand new

10311/2/1 Honeywell Controller module Brand new

In virtually all configurations, the C300 controller and Series C I/O provides useful, maintainable process equipment  connections in a smaller footprint than existing competitors and Honeywell equivalent products. Installing Series C I/O modules contributes to overall total installed cost savings.

Brand:HONEYWELL   Model number10311/2/1 

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

10311/2/1   Honeywell   Controller module Brand new


        

image.png




The Series C I/O is designed to allow integration with legacy of PM I/O family or replacement of

the legacy PM I/O family. As such, many PM I/O concepts are directly carried forward into Series C

I/O. Some notable concepts that are NOT directly carried forward are included in the table below.

Topic PM I/O

supported

Series C I/O

supported

Experion Yes Yes

PlantScape Yes No

TPS Yes No

Nomenclature IOP

I/O Processor

IOM

I/O Module

Physical address -

how to derive

Uses file and card concept Address derived from IO Link address

jumper tile on IOTA

DISOE 'Off Normal' alarms and events

supported

'Off Normal' alarms and events NOT

supported

Enumeration

sorting

By ordinal value Alphabetically, unless otherwise

stated.

FAILOPT or FAULT

[*]

FAILOPT is a IOP-wide configuration,

making it same to all channels in an

IOP

Series C FAILOPT is replaced with the

following:

l FAULTOPT, and

l FAULTVALUE

this can be set individually for every

output channel.

Firmware -

remotely

downloaded in

Experion

No - contact TAC for support Yes - using CTools application

HART I/O PMIO supported four separate AI, AO,

HAI and HAO channel blocks. AI and

AO channel blocks could not be

configured for HART operation

Series C I/O, AI and AO channel blocks

can be configured for HART operation.

No separate HAI and HAO channel

blocks will be supported.

HART 5.0 compliant Yes Yes

HART 6.0 and later Yes Yes

Table 14.1 Comparing Series C and PM I/O functionality

- 533 -

CHAPTER

14

Topic PM I/O

supported

Series C I/O

supported

compliant

IO redundancy All IOP types supported except:

l DI

l DO16

l LLAI

l LLMUX

l RHMUX

All IOM types supported except:

AI -LLMUX

IOLINK connection Yes (see Note 1)

Through C200 controller and IOLIM

or C300 controller

Yes (see Note 2)

C300 controller only

PM I/O and Series C I/O cannot exist

on the same IOLINK

PM I/O and Series C I/O cannot exist

on the same IOLINK

IOTA slots Any combination allowed Upper - always IOMA

Lower - always IOMB

Non-redundant configurations only

IOMA can be used.

LLMUX maximum

channels

32 64

PNTFORM (FULL

and COMPONENT

points) is supported

Yes No

The most powerful FULL point

features have been incorporated into

Series C I/O channel blocks.

Open Wire

Detection for

Inputs

Detect/sense open

sensor (open wire)

No Yes.

The HART Analog Output IOM detects

open wire by virtue of its analog read

back check.

DI 24V and DISOE IOM in Normal

mode support Open Wire Detection.

* Specifications for the availability of HART data, including availability through an IOM switchover

are tightened for Series C I/O.

Notes:

1. Physical address is a function of the 'file number' and 'card number'. The file number is

determined by a user jumper configuration. Logical address is assigned by user. Both

addresses must be configured in the module block and they are independent of one another.

The physical address block configuration must match the physical attributes.

2. Logical address is determined by a user jumper configuration. The physical address is a

function of the logical address and is not visible to the user. Only the logical address must be

configured in the module block. The logical address block configuration must match the

jumper configuration.


.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.