When installing a new battery, when there currently is no battery installed, the battery must be installed while the CPU has power. Failing to follow this procedure could result in the CPU not powering up. If a battery is installed while power is off (and there was no battery previously installed), and the CPU fails to power up, simply remove the battery, power cycle the CPU and then install the battery.
Brand: GE Model number:9F60MCB824
Colour:new Warranty: 1 year
Lead Time:3-day working day Country of origin: USA
Price: Please contact us Product weight:0.12kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
9F60MCB824 GE Programmable controller Brand new
Thermocouple module fails to power up
correctly
After some power loss events, the Horner Thermocouple module
(HE697THM160) may fail to power up successfully. After failure, the
%AI data will not be updated correctly and will continue to return zero
values. There are no module fault indicators for this event. The user
should power cycle again to restore normal function.
Fault contacts on modules in expansion
rack
When an expansion rack powers up, the slot fault contacts will
prematurely indicate that the modules in the expansion rack are not
faulted before they complete their power up. Use I/O point fault
contacts to verify validity of the I/O.
Fault contacts on Remote I/O Station If multiple faults exist in a Series 90-70 Remote I/O Station and one of
them is corrected, a FAULT contact that uses the Remote I/O Station’s
module reference will incorrectly indicate that no faults exist at the
Remote I/O Station.
BIT_SEQ function block DIR parameter The BIT_SEQ Function Block should require the user to flow
BOOLEAN logic into the DIR parameter, but currently does not. If no
DIR parameter is present, the BIT_SEQ will increment by default.
WinLoader may stop operating On computers running Windows 2000 and using some versions of
Symantec Antivirus protection, WinLoader will fail if used in advanced
mode. Recovery requires cycling the computer's power.
Logic and HWC not equal after power cycle If the Hardware Config from Target 1, with Logic/Configuration Powerup Source and Data Source both set to “Always from Flash,” is stored
in Flash, then Logic and Hardware Config from Target 2, with
Logic/Configuration Power-up Source both set to “Always from RAM,”
is stored to RAM and there is a good battery, then when power is
cycled the programmer may show that Logic and Hardware Config are
not equal. The remedy is to clear Flash and then store the Logic and
Hardware Config from Target 2.
GE DS3800DMEC1B1B
GE DS3800DMEC1C1C
GE DS3800DMEC1D1D
GE DS3800DMPC
GE DS3800DMPC1E1C
GE DS3800DMPC1F1E
GE DS3800DMPK1B1B
GE DS3800DMPK1E1D
GE DS3800DOAA
GE DS3800DPLA1B1A
GE DS3800DPSS1B1B
GE DS3800DPSS1C1C
GE DS3800DPZA1D1D
GE DS3800DSHA1A1A
GE DS3800DSHA1A1B
GE DS3800DSQD1A1A
GE DS3800DSWA
GE DS3800DXRA
GE DS3800DXRA1C1C
GE DS3800DXRC
GE DS3800DXRC1
GE DS3800HACA
GE DS3800HACA1A1A
GE DS3800HACB
GE DS3800HADA
GE DS3800HADA1A1A
GE DS3800HADA1B1B
GE DS3800HAFA1B1D
GE DS3800HAFA-1D1E
GE DS3800HAIA1D1B
GE DS3800HAIA1E1D
GE DS3800HAIA1EID
GE DS3800HAIC1A1A
GE DS3800HAIC1A1A 6BA00C
GE DS3800HAIC1A1A6BA00C
GE DS3800HAIC1E1C
GE DS3800HARA1B1C
GE DS3800HCIB
GE DS3800HCIB1B
GE DS3800HCIB1B1C
GE DS3800HCID
GE DS3800HCM1A1B
GE DS3800HCMA1E1G
GE DS3800HCMB
GE DS3800HCMB1C1C
GE DS3800HCMC
GE DS3800HCMC1A1B
GE DS3800HCMC-1A1B
GE DS3800HCVA1H1G
GE DS3800HCVA1J1G
GE DS3800HDDD
GE DS3800HDID1A1A
GE DS3800HDRA
GE DS3800HDRA1B
GE DS3800HDRA1B1B
GE DS3800HDRC1A1A
GE DS3800HFPB1F1E
GE DS3800HFPC
GE DS3800HFPC1L1H
GE DS3800HFPE1D1C
GE DS3800HFPG1C1B
GE DS3800HFPG1D1B
GE DS3800HFPG1D1C
GE DS3800HFPG1D1D
GE DS3800HFPG1E1E
GE DS3800HFXA1F1D
GE DS3800HFXB
GE DS3800HFXB1G1C
GE DS3800HFXB1R1H
GE DS3800HFXC
GE DS3800HFXD
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225