6KES243007X1A1  GE   Central control module Brand new

6KES243007X1A1 GE Central control module Brand new

The CPE010 and CPE020 can be field upgraded to CPU version 6.75 and Ethernet version 6.12 using the Winloader firmware upgrade utility and one of the following upgrade kits.

Brand: GE                 Model number: 6KES243007X1A1

Colour:new                  Warranty:  1 year

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.12kg

hipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

 6KES243007X1A1  GE   Central control module Brand new      

image.png

CPE010, CPE020, CRE020 indicates 

Stop/Fault during Winload 

Between the CPU and Ethernet portions of a firmware update on a 

CPE010, CPE020, or CRE020 Winloader will issue a “CPU STATE 

MISMATCH” dialog and prompt to place the CPU in Stop/No IO (IO 

Disabled) mode. To remedy this, click “Yes” to continue the upgrade.

Undefined symbols in C Blocks In Release 5.00 or later, if an attempt is made to download a C block 

containing undefined symbols, the download will fail. Machine Edition 

will display the following message in the Feedback Zone: Error 8097: 

Controller Error – Controller aborted the request [0x05][0xFF]

Prior to Release 5.00, C blocks containing undefined symbols could be 

successfully downloaded, but if they were executed the CPU would 

transition to Stop/Halt mode.

Length of serial I/O buffer (Release 5.0 or later) The "Set Up Input Buffer Function" will always 

allocate a buffer containing 2049 bytes. This is one byte more than 

previous PACSystems releases.

Only one BTM allowed in main rack Only one BTM is allowed in the main rack. Multiple BTMs in the main 

rack will result in undefined operation.

Upgrading firmware with modules in 

rack

The process of upgrading the CPU firmware with the WinLoader utility 

may fail when multiple IO modules are in the main, remote or 

expansion racks, due to the time it takes to power cycle the rack 

system. If the upgrade process fails, move the CPU to a rack without 

IO modules and restart the upgrade process.

Service Request 13 command block 

must contain zero

When the Service Request function block is used to invoke Service 

Request #13, the first word of the command block sets the number of 

last scans to be executed. If the value of that word is -1 (or 0xFFFF), 

then the number of last scans is set to the value in the configuration.

Changing IP address of Ethernet 

Interface while connected

Storing a hardware configuration with a new IP address to the RX7i 

while connected via Ethernet will succeed, then immediately 

disconnect because the RX7i is now using a different IP address than 

the Programmer. You must enter a new IP address in the Target 

Properties in the CME Inspector window before reconnecting.

.



 


GE    DS3800DMEC1B1B    

GE    DS3800DMEC1C1C    

GE    DS3800DMEC1D1D    

GE    DS3800DMPC    

GE    DS3800DMPC1E1C    

GE    DS3800DMPC1F1E    

GE    DS3800DMPK1B1B    

GE    DS3800DMPK1E1D    

GE    DS3800DOAA    

GE    DS3800DPLA1B1A    

GE    DS3800DPSS1B1B    

GE    DS3800DPSS1C1C    

GE    DS3800DPZA1D1D    

GE    DS3800DSHA1A1A    

GE    DS3800DSHA1A1B    

GE    DS3800DSQD1A1A    

GE    DS3800DSWA    

GE    DS3800DXRA    

GE    DS3800DXRA1C1C    

GE    DS3800DXRC    

GE    DS3800DXRC1    

GE    DS3800HACA    

GE    DS3800HACA1A1A    

GE    DS3800HACB    

GE    DS3800HADA    

GE    DS3800HADA1A1A    

GE    DS3800HADA1B1B    

GE    DS3800HAFA1B1D    

GE    DS3800HAFA-1D1E    

GE    DS3800HAIA1D1B    

GE    DS3800HAIA1E1D    

GE    DS3800HAIA1EID    

GE    DS3800HAIC1A1A    

GE    DS3800HAIC1A1A 6BA00C    

GE    DS3800HAIC1A1A6BA00C    

GE    DS3800HAIC1E1C    

GE    DS3800HARA1B1C    

GE    DS3800HCIB    

GE    DS3800HCIB1B    

GE    DS3800HCIB1B1C    

GE    DS3800HCID    

GE    DS3800HCM1A1B    

GE    DS3800HCMA1E1G    

GE    DS3800HCMB    

GE    DS3800HCMB1C1C    

GE    DS3800HCMC    

GE    DS3800HCMC1A1B    

GE    DS3800HCMC-1A1B    

GE    DS3800HCVA1H1G    

GE    DS3800HCVA1J1G    

GE    DS3800HDDD    

GE    DS3800HDID1A1A    

GE    DS3800HDRA    

GE    DS3800HDRA1B    

GE    DS3800HDRA1B1B    

GE    DS3800HDRC1A1A    

GE    DS3800HFPB1F1E    

GE    DS3800HFPC    

GE    DS3800HFPC1L1H    

GE    DS3800HFPE1D1C    

GE    DS3800HFPG1C1B    

GE    DS3800HFPG1D1B    

GE    DS3800HFPG1D1C    

GE    DS3800HFPG1D1D    

GE    DS3800HFPG1E1E    

GE    DS3800HFXA1F1D    

GE    DS3800HFXB    

GE    DS3800HFXB1G1C    

GE    DS3800HFXB1R1H    

GE    DS3800HFXC    

GE    DS3800HFXD    




You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225



    







Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.