For environmental specifications and compliance to standards (for example, FCC or European Union Directives), refer to Appendix A of the PACSystems RX7i Installation Manual, GFK-2223.


Brand: GE                 Model number:531X182IFGAGG1 

Colour:new                  Warranty:  1 year

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.12kg

hipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

531X182IFGAGG1  GE  Central control module Brand new

 

image.png 

SRTP connections remain open after IP 

address changed

The Ethernet Interface does not terminate all open SRTP connections 

before changing its IP address. Once the local IP address has changed, 

any existing open TCP connections are unable to normally terminate. This 

can leave SRTP connections open until their underlying TCP connections 

time out. If quicker recovery of the SRTP connection is needed, modify 

the “wkal_idle” Advanced User Parameter to reduce the TCP keep alive 

timer down to the desired maximum time for holding open the broken 

connection. Refer to TCP/IP Ethernet Communications for PACSystems, 

GFK-2224, for details.

CPU time used for produced EGD 

Timestamps

Changing the Ethernet interface time via the CHTIME command does not 

affect the timestamp value within EGD exchanges produced from this 

Ethernet interface. The EGD timestamp value reflects the current CPU 

time. In Series 90-70 products and the Series 90-30 CPU364, EGD 

timestamps are taken from the Ethernet interface and do reflect CHTIME 

modifications.

ENIU stale data during run mode store 

of EGD

In a large PPS system running 20 ENIUs, when a Run-mode Store is 

performed that deletes the EGD exchanges for 10 of the ENIUs, the other 

ENIUs will see the status on their exchanges indicate consumption 

timeouts during the RMS. At the completion of the RMS, the exchanges 

operate normally.

Internet Explorer 8 may require setting 

changes when using Web pages on 

RX7i

It may be required to disable the pop-up blocker when using Internet 

Explorer 8 with the Web pages supplied with the RX7i Ethernet firmware. 

To disable the pop-up blocker, in the Internet Explorer toolbar, select

Tools->Pop-up Blocker->Turn Off Pop-up Blocker

Note: If you have the Google toolbar installed, the Google pop-up 

blocker may also have to be disabled. 

It may also be required to disable configuration scripts when using 

Internet Explorer 8. In the Toolbar select Internet Options. In the Internet 

Options dialog box click the “Connections” tab, click the “LAN settings” 

button, and make sure the box beside “Automatically detect settings” has 

a check in it. If it does not, click the box next to “Automatically detect 

settings” to enable this setting.


 


GE    DS3800DMEC1B1B    

GE    DS3800DMEC1C1C    

GE    DS3800DMEC1D1D    

GE    DS3800DMPC    

GE    DS3800DMPC1E1C    

GE    DS3800DMPC1F1E    

GE    DS3800DMPK1B1B    

GE    DS3800DMPK1E1D    

GE    DS3800DOAA    

GE    DS3800DPLA1B1A    

GE    DS3800DPSS1B1B    

GE    DS3800DPSS1C1C    

GE    DS3800DPZA1D1D    

GE    DS3800DSHA1A1A    

GE    DS3800DSHA1A1B    

GE    DS3800DSQD1A1A    

GE    DS3800DSWA    

GE    DS3800DXRA    

GE    DS3800DXRA1C1C    

GE    DS3800DXRC    

GE    DS3800DXRC1    

GE    DS3800HACA    

GE    DS3800HACA1A1A    

GE    DS3800HACB    

GE    DS3800HADA    

GE    DS3800HADA1A1A    

GE    DS3800HADA1B1B    

GE    DS3800HAFA1B1D    

GE    DS3800HAFA-1D1E    

GE    DS3800HAIA1D1B    

GE    DS3800HAIA1E1D    

GE    DS3800HAIA1EID    

GE    DS3800HAIC1A1A    

GE    DS3800HAIC1A1A 6BA00C    

GE    DS3800HAIC1A1A6BA00C    

GE    DS3800HAIC1E1C    

GE    DS3800HARA1B1C    

GE    DS3800HCIB    

GE    DS3800HCIB1B    

GE    DS3800HCIB1B1C    

GE    DS3800HCID    

GE    DS3800HCM1A1B    

GE    DS3800HCMA1E1G    

GE    DS3800HCMB    

GE    DS3800HCMB1C1C    

GE    DS3800HCMC    

GE    DS3800HCMC1A1B    

GE    DS3800HCMC-1A1B    

GE    DS3800HCVA1H1G    

GE    DS3800HCVA1J1G    

GE    DS3800HDDD    

GE    DS3800HDID1A1A    

GE    DS3800HDRA    

GE    DS3800HDRA1B    

GE    DS3800HDRA1B1B    

GE    DS3800HDRC1A1A    

GE    DS3800HFPB1F1E    

GE    DS3800HFPC    

GE    DS3800HFPC1L1H    

GE    DS3800HFPE1D1C    

GE    DS3800HFPG1C1B    

GE    DS3800HFPG1D1B    

GE    DS3800HFPG1D1C    

GE    DS3800HFPG1D1D    

GE    DS3800HFPG1E1E    

GE    DS3800HFXA1F1D    

GE    DS3800HFXB    

GE    DS3800HFXB1G1C    

GE    DS3800HFXB1R1H    

GE    DS3800HFXC    

GE    DS3800HFXD    




You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225



    







Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.