531X112PSAARG1 531X112PSAAR 531X112  GE  Input module Brand new

531X112PSAARG1 531X112PSAAR 531X112 GE Input module Brand new

The CPE330 is programmed and configured 

over Ethernet via GE’s Proficy* Machine 

Edition (PME) software. It resides in the RX3i 

main rack and supports all RX3i I/O and 

Intelligent Option modules, up to 32K I/O 

points.


Brand: GE                 Model number:531X112PSAARG1

Colour:new                  Warranty:  1 year

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.12kg

hipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

531X112PSAARG1 531X112PSAAR 531X112  GE  Input module Brand new


image.png 

Reporting of duplicate IP address The PACSystems RX7i does not log an exception or a fault in the 

Controller Fault Table when it detects a duplicate IP address on the 

network. 

Multiple zero period EGD exchanges 

may not produce similar numbers of 

samples

If more than one EGD produced exchange is configured for a production 

period of zero, the exchanges may not produce similar numbers of 

samples. Due to the way that scheduling occurs when multiple exchanges 

are scheduled “as fast as possible,” some zero period exchanges may 

produce significantly more samples than others. For more consistent EGD 

production, configure the produced EGD exchanges with non-zero 

production periods.

Changing IP address while SRTP 

connection open may generate log 

events

Open SRTP Server connections established with a remote SRTP client 

are not terminated as expected when the RX7i’s IP address is changed 

(typically by storing a new HW Configuration to the RX7i). A Series 90 

SRTP client (“SRTP channels”) reports either a 9690H or 0190H status; 

the SRTP connection may remain open until the connection is terminated 

as a result of a client timeout. 

Series 90-70 datagrams are not 

supported

Series 90-70 datagrams are not supported. This means that Series 90-70 

- format variable list requests from Host Comm Toolkit applications will 

fail. (Series 90-30 – format datagrams are supported, but cannot access 

%P or %L memory in the RX7i.) 

AUP parameter should not be changed The Advanced User Parameter “wsnd_buf” should not be changed by the 

user. Changing the value of this parameter may cause the LAN LED to go 

out and the Ethernet Interface to drop connection.

Heavy load can block station manager As explained in TCP/IP Communications for PACSystems Station 

Manager Manual, GFK-2225, Chapter 1, a heavy EGD and/or SRTP load 

can block Station Manager operation. 

One-time delay of EGD Production (and 

possibly Consumption) if more than 24 

SRTP Server Connections are started 

simultaneously

If more than 24 SRTP Server connections are established simultaneously, 

EGD Production may be briefly delayed for each connection after the 24th

when the connections are first made after power is applied. If EGD 

consume acceleration has been disabled, then EGD Consumption will 

also be delayed. The delay only occurs once when the SRTP Server 

connection is established for the first time after Powerup. No delay is 

experienced for the first 24 SRTP Server connections.

Very Heavy EGD 

production/consumption at server may 

cause EGD command timeouts

Very heavy EGD production and/or consumption at a server device may 

cause EGD command timeout errors when another device attempts to 

send EGD commands to that server. If EGD commands must preempt 

normal production, you may set the “gcmd_pri” Advanced User Parameter 

to 2 (see GFK-2224, Appendix A). Note that by doing so, EGD exchange 

production may be delayed.


 


GE    DS3800DMEC1B1B    

GE    DS3800DMEC1C1C    

GE    DS3800DMEC1D1D    

GE    DS3800DMPC    

GE    DS3800DMPC1E1C    

GE    DS3800DMPC1F1E    

GE    DS3800DMPK1B1B    

GE    DS3800DMPK1E1D    

GE    DS3800DOAA    

GE    DS3800DPLA1B1A    

GE    DS3800DPSS1B1B    

GE    DS3800DPSS1C1C    

GE    DS3800DPZA1D1D    

GE    DS3800DSHA1A1A    

GE    DS3800DSHA1A1B    

GE    DS3800DSQD1A1A    

GE    DS3800DSWA    

GE    DS3800DXRA    

GE    DS3800DXRA1C1C    

GE    DS3800DXRC    

GE    DS3800DXRC1    

GE    DS3800HACA    

GE    DS3800HACA1A1A    

GE    DS3800HACB    

GE    DS3800HADA    

GE    DS3800HADA1A1A    

GE    DS3800HADA1B1B    

GE    DS3800HAFA1B1D    

GE    DS3800HAFA-1D1E    

GE    DS3800HAIA1D1B    

GE    DS3800HAIA1E1D    

GE    DS3800HAIA1EID    

GE    DS3800HAIC1A1A    

GE    DS3800HAIC1A1A 6BA00C    

GE    DS3800HAIC1A1A6BA00C    

GE    DS3800HAIC1E1C    

GE    DS3800HARA1B1C    

GE    DS3800HCIB    

GE    DS3800HCIB1B    

GE    DS3800HCIB1B1C    

GE    DS3800HCID    

GE    DS3800HCM1A1B    

GE    DS3800HCMA1E1G    

GE    DS3800HCMB    

GE    DS3800HCMB1C1C    

GE    DS3800HCMC    

GE    DS3800HCMC1A1B    

GE    DS3800HCMC-1A1B    

GE    DS3800HCVA1H1G    

GE    DS3800HCVA1J1G    

GE    DS3800HDDD    

GE    DS3800HDID1A1A    

GE    DS3800HDRA    

GE    DS3800HDRA1B    

GE    DS3800HDRA1B1B    

GE    DS3800HDRC1A1A    

GE    DS3800HFPB1F1E    

GE    DS3800HFPC    

GE    DS3800HFPC1L1H    

GE    DS3800HFPE1D1C    

GE    DS3800HFPG1C1B    

GE    DS3800HFPG1D1B    

GE    DS3800HFPG1D1C    

GE    DS3800HFPG1D1D    

GE    DS3800HFPG1E1E    

GE    DS3800HFXA1F1D    

GE    DS3800HFXB    

GE    DS3800HFXB1G1C    

GE    DS3800HFXB1R1H    

GE    DS3800HFXC    

GE    DS3800HFXD    




You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225



    







Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.