469-P5-HI-A20-E  GE  Controller module Brand new

469-P5-HI-A20-E GE Controller module Brand new

When installing a new battery, when there currently is no battery installed, the battery must be installed while the CPU has power. Failing to follow this procedure could result in the CPU not powering up.

Brand: GE                 Model number:469-P5-HI-A20-E

Colour:new                  Warranty: 44C372638-G01

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.12kg

hipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

469-P5-HI-A20-E  GE  Controller module Brand new  

image.png 

 EGD command range failure can write 
partial data to RX7i bit memory 
When an EGD Command attempts a write operation to a bit-mode 
reference memory range (%I, %Q; %T, %M, %SA, %SB, %SC) where the 
amount of data be written exceeds the configured size of that reference 
memory, the command will return failure status but partial data may be 
written into the reference memory. The amount of partial data written 
depends upon the starting bit memory location and the data length as 
follows:
 If data starts on a byte boundary (location = (8*n) + 1), no partial data 
is written.
 If data does not start on a byte boundary (location = (8*n)+1) and 
data exceeds the configured reference memory by 8 or more bits, 
partial data is written from the starting location to the next byte 
boundary after the starting location.
 If data does not start on a byte boundary (location = (8*n)+1) and 
data exceeds the configured reference memory by less than 8 bits, 
partial data is written from the stating location to the end of configured 
reference memory.
For a Write PLC Memory command, this can occur when writing data into 
the target PLC. For Read PLC Memory or Read Exchange commands, 
this can occur when writing data received from the target controller into 
the local memory. The logic application must not use any data returned to 
the local controller if the EGD command status indicates failure.
To avoid writing partial data to the local or remote controller, be sure that 
bit memory data transfers do not exceed the configured reference 
memory sizes at the appropriate controller. 
No CPU fault logged when Ethernet 
Interface in fatal blink code
The CPU does not log any Controller or I/O Faults when the Ethernet 
Interface has a fatal blink code. The user’s application should monitor the 
LAN interface OK status bit to detect loss of module.
EGD I/O has unexpected variability 
under heavy load
EGD I/O has intermittent unexpected variability under heavy load. For a 
Produced Exchange, EGD samples may occasionally be delayed by as 
much as a production period or more.
Clear of large hardware configurations 
may cause log event 08/20
A Log event 08/20 may occur when very large hardware configurations 
are cleared and transfers are active on other Server connections. This log 
event can be safely ignored.
COMMREQ Status Word of 0x54A0 
occasionally returned for EGD 
commands
Occasional COMMREQ Status Word values of 0x54A0 are returned to 
COMMREQs for EGD commands when the previously transferred 
command has experienced retries in the network. Executing the 
COMMREQ again results in successful transfer of the command.
Modbus/TCP channel aborted during 
power cycle
After powering up an RX7i running Modbus/TCP client channels, the 
establish connection occasionally fails because the server occasionally 
rejects the "open" from the client. The connection will then succeed if the 
application retries the open when it sees a 0x9690, 0xAA90, or B490H 
response to an open request or to the first write request. 


 


GE    DS3800DMEC1B1B    

GE    DS3800DMEC1C1C    

GE    DS3800DMEC1D1D    

GE    DS3800DMPC    

GE    DS3800DMPC1E1C    

GE    DS3800DMPC1F1E    

GE    DS3800DMPK1B1B    

GE    DS3800DMPK1E1D    

GE    DS3800DOAA    

GE    DS3800DPLA1B1A    

GE    DS3800DPSS1B1B    

GE    DS3800DPSS1C1C    

GE    DS3800DPZA1D1D    

GE    DS3800DSHA1A1A    

GE    DS3800DSHA1A1B    

GE    DS3800DSQD1A1A    

GE    DS3800DSWA    

GE    DS3800DXRA    

GE    DS3800DXRA1C1C    

GE    DS3800DXRC    

GE    DS3800DXRC1    

GE    DS3800HACA    

GE    DS3800HACA1A1A    

GE    DS3800HACB    

GE    DS3800HADA    

GE    DS3800HADA1A1A    

GE    DS3800HADA1B1B    

GE    DS3800HAFA1B1D    

GE    DS3800HAFA-1D1E    

GE    DS3800HAIA1D1B    

GE    DS3800HAIA1E1D    

GE    DS3800HAIA1EID    

GE    DS3800HAIC1A1A    

GE    DS3800HAIC1A1A 6BA00C    

GE    DS3800HAIC1A1A6BA00C    

GE    DS3800HAIC1E1C    

GE    DS3800HARA1B1C    

GE    DS3800HCIB    

GE    DS3800HCIB1B    

GE    DS3800HCIB1B1C    

GE    DS3800HCID    

GE    DS3800HCM1A1B    

GE    DS3800HCMA1E1G    

GE    DS3800HCMB    

GE    DS3800HCMB1C1C    

GE    DS3800HCMC    

GE    DS3800HCMC1A1B    

GE    DS3800HCMC-1A1B    

GE    DS3800HCVA1H1G    

GE    DS3800HCVA1J1G    

GE    DS3800HDDD    

GE    DS3800HDID1A1A    

GE    DS3800HDRA    

GE    DS3800HDRA1B    

GE    DS3800HDRA1B1B    

GE    DS3800HDRC1A1A    

GE    DS3800HFPB1F1E    

GE    DS3800HFPC    

GE    DS3800HFPC1L1H    

GE    DS3800HFPE1D1C    

GE    DS3800HFPG1C1B    

GE    DS3800HFPG1D1B    

GE    DS3800HFPG1D1C    

GE    DS3800HFPG1D1D    

GE    DS3800HFPG1E1E    

GE    DS3800HFXA1F1D    

GE    DS3800HFXB    

GE    DS3800HFXB1G1C    

GE    DS3800HFXB1R1H    

GE    DS3800HFXC    

GE    DS3800HFXD    




You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225



    







Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.