44C331889-G01  GE   Central control module Brand new

44C331889-G01 GE Central control module Brand new

Extended Terminal Block IC694TBB132 comes with an 

outer cover that is approximately ½-inch (13mm) deeper than Terminal Block IC694TBB032, to accommodate wires with thicker insulation, such as that typically used with AC I/O modules.


Brand: GE                 Model number:44C331883G01

Colour:new                  Warranty: 44C331889-G01

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.12kg

hipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

44C331889-G01  GE   Central control module Brand new

image.png 

Large number of COMMREQs sent to 

module in one sweep causes faults

A large number of COMMREQs (typically greater than 8) sent to a 

given board in the same sweep may cause Module Software faults to 

be logged in the Controller fault table. The fault group is 

MOD_OTHR_SOFTWR (16t, 10h) and the error code is 

COMMREQ_MB_FULL_START (2). When this occurs, the “FT” output 

of the function block will also be set. To prevent this situation, 

COMMREQs issued to a given board should be spread across 

multiple sweeps so that only a limited number (typically 8 or less) of 

COMMREQs are sent to a given board in each sweep. In addition, the 

FT output parameter should be checked for errors. If the FT output is 

set (meaning an error has been detected), the COMMREQ could be 

re-issued by the application logic.

C Block standard math functions do not 

set errno

In C Blocks, standard math functions (e.g. sqrt, pow, asin, acos) do 

not set errno to the correct value and do not return the correct value if 

an invalid input is provided.

Loss of VDD100, VAL132 or VME-1182A 

after multiple power cycles

In rare instances, a VDD100, VAL132, or VME-1182A module may not 

configure after power has cycled repeatedly in a very brief period of 

time. A Loss of IO Module fault will be generated. 

In extremely rare instances, this may also cause other modules to fail 

to configure, without generating additional loss of module faults. 

These additional failures may cause communication with the Ethernet 

Interface to fail.

The user can recover from either of these cases by turning off power 

for at least 5 seconds and then restoring power. This will provide 

sufficient "off-time" to ensure that all modules can power up properly.

Modules not reset during firmware 

upgrades

The RX7i currently does not reset any other modules in the system 

after a firmware upgrade. This may result in Loss of module faults 

being generated for smart modules. 

Unable to communicate through some 

third party serial cards

PACS Systems serial ports do not work with some third party serial 

cards.

Incorrect COMMREQ status for invalid 

program name

The program name for PACSystems is always "LDPROG1". When 

another program name is used in a COMMREQ accessing %L 

memory, the error that is generated is 05D5, which is an invalid block 

name.


GE    DS3800DMEC1B1B    

GE    DS3800DMEC1C1C    

GE    DS3800DMEC1D1D    

GE    DS3800DMPC    

GE    DS3800DMPC1E1C    

GE    DS3800DMPC1F1E    

GE    DS3800DMPK1B1B    

GE    DS3800DMPK1E1D    

GE    DS3800DOAA    

GE    DS3800DPLA1B1A    

GE    DS3800DPSS1B1B    

GE    DS3800DPSS1C1C    

GE    DS3800DPZA1D1D    

GE    DS3800DSHA1A1A    

GE    DS3800DSHA1A1B    

GE    DS3800DSQD1A1A    

GE    DS3800DSWA    

GE    DS3800DXRA    

GE    DS3800DXRA1C1C    

GE    DS3800DXRC    

GE    DS3800DXRC1    

GE    DS3800HACA    

GE    DS3800HACA1A1A    

GE    DS3800HACB    

GE    DS3800HADA    

GE    DS3800HADA1A1A    

GE    DS3800HADA1B1B    

GE    DS3800HAFA1B1D    

GE    DS3800HAFA-1D1E    

GE    DS3800HAIA1D1B    

GE    DS3800HAIA1E1D    

GE    DS3800HAIA1EID    

GE    DS3800HAIC1A1A    

GE    DS3800HAIC1A1A 6BA00C    

GE    DS3800HAIC1A1A6BA00C    

GE    DS3800HAIC1E1C    

GE    DS3800HARA1B1C    

GE    DS3800HCIB    

GE    DS3800HCIB1B    

GE    DS3800HCIB1B1C    

GE    DS3800HCID    

GE    DS3800HCM1A1B    

GE    DS3800HCMA1E1G    

GE    DS3800HCMB    

GE    DS3800HCMB1C1C    

GE    DS3800HCMC    

GE    DS3800HCMC1A1B    

GE    DS3800HCMC-1A1B    

GE    DS3800HCVA1H1G    

GE    DS3800HCVA1J1G    

GE    DS3800HDDD    

GE    DS3800HDID1A1A    

GE    DS3800HDRA    

GE    DS3800HDRA1B    

GE    DS3800HDRA1B1B    

GE    DS3800HDRC1A1A    

GE    DS3800HFPB1F1E    

GE    DS3800HFPC    

GE    DS3800HFPC1L1H    

GE    DS3800HFPE1D1C    

GE    DS3800HFPG1C1B    

GE    DS3800HFPG1D1B    

GE    DS3800HFPG1D1C    

GE    DS3800HFPG1D1D    

GE    DS3800HFPG1E1E    

GE    DS3800HFXA1F1D    

GE    DS3800HFXB    

GE    DS3800HFXB1G1C    

GE    DS3800HFXB1R1H    

GE    DS3800HFXC    

GE    DS3800HFXD    




You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225



    







Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.